Flow Cytometry Core Virtual Tour Video
Nebraska Center for Biotechnology
Author
06/02/2021
Added
193
Plays
Description
Virtual tour of the Flow Cytometry Core Facility. The Flow Cytometry Core provides comprehensive data collection and analysis, cell sorting, multi-parameter panel design assistance, education and training in flow cytometry and application consultation.
Searchable Transcript
Toggle between list and paragraph view.
- [00:00:00.941](bright upbeat music)
- [00:00:08.520]Welcome to the Flow Cytometry Laboratory.
- [00:00:10.350]We are located in North Wing
- [00:00:11.660]of the Morrison Life Science Research Center
- [00:00:13.670]on the first floor.
- [00:00:14.800]For more details on how to find that facility,
- [00:00:16.540]please email me.
- [00:00:17.890]The laboratory is large and easy to social distance
- [00:00:20.400]and we have open bench space available
- [00:00:22.050]and a centrifuge for use if users wish
- [00:00:24.610]to prepare their samples in the lab.
- [00:00:26.810]The center is open for business Monday through Friday
- [00:00:28.980]from 8:00 to 5:00,
- [00:00:30.340]evening and weekend access may be granted to users
- [00:00:32.460]with appropriate training.
- [00:00:34.600]At the moment, the center has two primary instruments
- [00:00:36.820]to meet researchers needs.
- [00:00:38.270]The newest addition to the facility
- [00:00:39.680]is the Beckman Coulter CytoFLEX LX analysis system.
- [00:00:43.030]The CytoFLEX is equipped with four laser lines
- [00:00:45.500]and 16 fluorescence detectors.
- [00:00:47.920]It is driven by the intuitive site expert software
- [00:00:50.760]and I do offer training on this system
- [00:00:52.220]if users are interested in running their own experiments
- [00:00:54.670]or I will be happy to run experiments for customers.
- [00:00:57.470]In addition to the fluorescent detectors,
- [00:00:59.250]it is also equipped with extremely sensitive
- [00:01:01.160]forward and side scatter detectors
- [00:01:02.960]that are capable of visualizing particles
- [00:01:04.720]as small as 300 nanometers.
- [00:01:06.680]So it is capable of analyzing extracellular vesicles
- [00:01:10.120]and even other nanoparticles.
- [00:01:12.770]Most of the work that is done on the system
- [00:01:14.330]is looking at multi-parameter fluorescence panels
- [00:01:16.860]with an option to load samples into 96-well plate
- [00:01:19.430]for automatic acquisition.
- [00:01:21.100]It has proven to be the lab's workhorse.
- [00:01:23.690]The other main system in the lab
- [00:01:25.100]is our BD FACSAria II cell sorter.
- [00:01:27.510]This system also has four laser lines working
- [00:01:29.720]with 17 fluorescence detectors
- [00:01:31.760]and can be used for analysis if necessary.
- [00:01:34.110]But the real benefit of this system
- [00:01:35.580]is that it is capable of collecting
- [00:01:37.030]and purifying specific subsets from the sample.
- [00:01:39.960]For example, if you are working with a transfected cell line
- [00:01:42.940]and you only want to work with the GFP-positive cells,
- [00:01:45.810]we can run the sample through this order
- [00:01:47.240]and collect and isolate only the cells
- [00:01:49.000]that have expression of GFP
- [00:01:51.040]while removing all the negatives.
- [00:01:53.180]You could also sort your GFP containing cells directly
- [00:01:55.610]into a multi-well plate
- [00:01:56.830]as few as one cells per well if needed
- [00:01:59.780]and put them back into culture to grow further.
- [00:02:02.160]The sorter is housed in the biosafety cabinet
- [00:02:04.140]for user and staff protection
- [00:02:05.770]and because of that,
- [00:02:06.603]we were able to work with BSL-2 Plus level samples.
- [00:02:10.180]We also welcome users who are external
- [00:02:11.870]to the university to come and use our facilities.
- [00:02:14.630]Our prices are listed on our website.
- [00:02:16.430]And the lab does offer free consultations
- [00:02:18.330]if you would like to discuss
- [00:02:19.310]whether the Flow Lab would be useful for your research.
- [00:02:22.000]Please feel free to reach out to me
- [00:02:23.380]if you have any questions
- [00:02:24.730]about experiments that you would like to discuss.
- [00:02:26.805](bright upbeat music)
The screen size you are trying to search captions on is too small!
You can always jump over to MediaHub and check it out there.
Log in to post comments
Embed
Copy the following code into your page
HTML
<div style="padding-top: 56.25%; overflow: hidden; position:relative; -webkit-box-flex: 1; flex-grow: 1;"> <iframe style="bottom: 0; left: 0; position: absolute; right: 0; top: 0; border: 0; height: 100%; width: 100%;" src="https://mediahub.unl.edu/media/17089?format=iframe&autoplay=0" title="Video Player: Flow Cytometry Core Virtual Tour Video" allowfullscreen ></iframe> </div>